TH-GC Series Layer2 Manaʻo ʻia ʻo Ethernet Switch 4xGigabit Combo(RJ45/SFP) 16×10/ 100/ 1000Base-T PoE/24×10/ 100/ 1000Base-T PoE
ʻO Gigabit Layer 2 Managed PoE Switch he Green Energy-Saving PoE Switch kūʻokoʻa. Me ka IC Network kiʻekiʻe a me ka wikiwiki a me ka PoE Chip paʻa loa, hui nā awa PoE me IEEE802.3af 15.4w a me IEEE802.3at 30w. Hiki i kēia kŘkohu ke hāʻawi i ka pilina maʻemaʻe no ka 10/100/1000M Ethernet, a hiki i ke awa mana PoE ke ʻike pono a hoʻoikaika i nā mea mana e hoʻokō me IEEE802.3af/ma nā kūlana. Hoʻohana ʻia nā mea ʻaʻole PoE a hoʻouna wale i ka ʻikepili.
● Hoʻololi i ka ʻikepili no nā kiʻi paʻi kiʻi pūnaewele
● Kākoʻo iā IEEE802.3/ IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, hale kūʻai-a-mua
● He kūpono me IEEE802.3at (30W) a me IEEE802.3af (15.4w)
● Kākoʻo ke awa Ethernet i 10/100/1000M adaptive a me nā hana PoE
● Hōʻike hōʻike Panel e nānā i ke kūlana a kōkua i ka nānā ʻole ʻana
● Kākoʻo i ka hōʻoia port 802.1x, kākoʻo i ka hōʻoia AAA, kākoʻo i ka hōʻoia TACACS +; Nā hoʻonohonoho pale kaua DOS, nā hoʻonohonoho ACL
● Kākoʻo iā WEB, TELNET, CLI, SSH, SNMP, RMON hoʻokele
● Kākoʻo PoE Power Management a me PoE Watchdog
● Hoʻonui ʻia o ka Uila: ʻO ke ʻano maʻamau 4KV, ʻano ʻokoʻa 2KV, ESD 15KV
| P/N | wehewehe |
| TH-GC0416PM2-Z200W | Layer2 Managed Ethernet Switch 4x1Gigabit Combo (RJ45/SFP)16×10/ 100/ 1000Base-T PoE Port, Hāʻawi Mana Kūloko 52V/3.8A, 200w |
| TH-GC0416PM2-Z300W | Layer2 Managed Ethernet Switch 4x1Gigabit Combo (RJ45/SFP)16×10/ 100/ 1000Base-T PoE Port , Hāʻawi Mana Kūloko 52V/5.76A, 300w |
| TH-GC0424PM2-Z300W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/ 100/ 1000Base-T PoE Port, Hāʻawi Mana Kūloko 52V/5.76A, 300w |
| TH-GC0424PM2-Z400W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/ 100/ 1000Base-T PoE Port, Hāʻawi Mana Kūloko 52V/7.69A, 400w |
| I/O Interface | ||
| Hookomo mana | Hoʻokomo AC 110-240V, 50/60Hz | |
| Awa Paa | P/N | Awa Paa |
| TH-GC0416PM2-Z200w | 16 x 10/ 100/ 1000Mbps Puka PoE | |
| 4 x 1000M Combo (RJ45/SFP) Awa | ||
| 1 x RJ45 Console Port | ||
| TH-GC0416PM2-Z300w | 16 x 10/ 100/ 1000Mbps Puka PoE | |
| 4 x 1000M Combo (RJ45/SFP) Awa | ||
| 1 x RJ45 Console Port | ||
| TH-GC0424PM2-Z300w | 24 x 10/ 100/ 1000Mbps Puka PoE | |
| 4 x 1000M Combo (RJ45/SFP) Awa | ||
| 1 x RJ45 Console Port | ||
| TH-GC0424PM2-Z400w | 24 x 10/ 100/ 1000Mbps Puka PoE | |
| 4 x 1000M Combo (RJ45/SFP) Awa | ||
| 1 x RJ45 Console Port | ||
| hana | ||
| Hiki ke hoololi | 56Gbps | |
| Ka holo ana | 41.66Mpps | |
| Pākuʻi Paʻa | 4Mb | |
| Hoʻomanaʻo Flash | 16MB | |
| DDR SDRAM | 128MB | |
| Wahi MAC | 8K | |
| Pākuʻi Jumbo | 9.6Kbytes | |
| Nā VLAN | 4096 | |
| Ke ano hoololi | E kūʻai a i mua | |
| MTBF | 100000 hola | |
| Kūlana | ||
| ʻO ka protocol network | IEEE 802.3: Ethernet MAC Protocol | |
| IEEE 802.3i: 10BASE-T Ethernet | ||
| IEEE 802.3u: 100BASE-TX Ethernet wikiwiki | ||
| IEEE 802.3ab: 1000BASE-T Gigabit Ethernet | ||
| IEEE 802.3z: 1000BASE-X Gigabit Ethernet (wiaweo ʻōpika) | ||
| IEEE 802.3az: ʻO Ethernet ʻoi loa ka ikehu | ||
| IEEE 802.3ad: ʻO ke ala maʻamau no ka hoʻokō ʻana i ka hōʻuluʻulu loulou | ||
| IEEE 802.3x: Kaohi kahe | ||
| IEEE 802.1ab: LLDP/LLDP-MED (Hoʻohui Layer Discovery Protocol) | ||
| IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Prioritization (Multicast | ||
| hana kānana) | ||
| IEEE 802.1q: Hana Alahaka VLAN | ||
| IEEE 802.1x: Kākoʻo Manaʻo Kākoʻo/Server Access Control a Authentication Protocol | ||
| IEEE 802.1d: STP; IEEE 802.1s: MSTP; IEEE 802.1w: RSTP | ||
| PoE Protocol | IEEE802.3af (15.4W); IEEE802.3at (30W) | |
| ʻOihana Kūlana | EMI: FCC Māhele 15 CISPR (EN55032) papa A | |
| EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 (Surge) | ||
| Haʻalulu: IEC 60068-2-27 | ||
| Hāʻule manuahi: IEC 60068-2-32 | ||
| Kuʻi: IEC 60068-2-6 | ||
| Pūnaehana Waena | 10Base-T: Cat3, 4, 5 a i ʻole UTP (≤100m) | |
| 100Base-TX: Cat5 a i ʻole UTP (≤100m) | ||
| 1000Base-TX: Cat5 a i ʻole UTP (≤100m) Optical | ||
| Multimode fiber: 1310nm, 2Km | ||
| ʻO ka fiber mode hoʻokahi: 1310nm, 20/40 Km; 1550nm, 60/80/100/120Km | ||
| Palekana | ||
| Palapala Palekana | CE/FCC/RoHS | |
| Kaiapuni | ||
| Kaiapuni Hana | Ka Mahana Hana: -20~55°C | |
| Ka Mahana Waihona: -40~85°C | ||
| Ka haʻahaʻa hana: 10% ~ 90%,condensing ole | ||
| Ka Mahana Waihona: 5%~90%,condensing ole | ||
| Kiʻekiʻe o ka hana: 10,000 kapuaʻi kiʻekiʻe | ||
| Ke kiʻekiʻe o ka mālama ʻana: 10,000 kapuaʻi kiʻekiʻe | ||
| Hōʻike | ||
| Nā hōʻailona LED | PWR (ka lako mana) | |
| SYS (Pūnaewele) | ||
| 1-24 PoE & ACT (PoE) | ||
| 1-24 Link & ACT (Login & Act) | ||
| 25-28 Loulou (Lulu) | ||
| 25-28 Act (Act) | ||
| Hoʻololi DIP | Hoʻoponopono hou | |
| Mekanika | ||
| Ka nui o ka hale | Ana Huahana (L*W*H): 440* 284*44mm | |
| Ka nui o ka pūʻolo (L * W * H): 495 * 350 * 103mm | ||
| NW: 3.5kg | ||
| GW: 4.25 kg | ||
| ʻIkepili Hoʻopili | Kāleka MEAS: 592 * 510 * 375mm | |
| Pākuʻi Qty: 5 ʻāpana | ||
| Pāpaʻa Kaumaha: 22.5KG | ||
| Hana polokalamu Layer 2 | ||
| Hooponopono awa | Ho'ā/Hoʻopau i ke awa | |
| Ka wikiwiki, Duplex, MTU Hoʻonohonoho | ||
| Kahe-hoomalu | ||
| Nānā ʻIke Awa | ||
| Awa Mirroring | Kākoʻo ʻelua ʻaoʻao ʻaoʻao hoʻohālikelike awa | |
| Ka palena māmā awa | Kākoʻo ia i ka hoʻokele bandwidth hoʻokomo / puka puka | |
| Kaawale awa | Kākoʻo i ka hoʻokaʻawale ʻana i ke awa iho, a hiki ke kamaʻilio me ke awa uplink | |
| Kāohi ʻino | Kākoʻo i ka unicast ʻike ʻole, multicast, multicast ʻike ʻole, hoʻopaʻa ʻia ʻano ʻino | |
| Hoʻopau ʻino ma muli o ka hoʻoponopono bandwidth a me ke kānana ʻino | ||
| Hui Hui | Kākoʻo i ka hōʻuluʻulu manual static | |
| Kākoʻo i ka LACP dynamic aggregation | ||
| VLAN | Komo | |
| Puku | ||
| Huinaʻi | ||
| Kākoʻo port, protocol, MAC-based VLAN partitioning | ||
| Kākoʻo iā GVRP dynamic VLAN hoʻopaʻa inoa | ||
| VLAN leo | ||
| MAC | Kākoʻo i ka hoʻohui static, holoi | |
| palena aʻo helu MAC | ||
| Kākoʻo i ka hoʻonohonoho manawa ʻelemakule | ||
| lāʻau Spanning | Kākoʻo STP spanning tree protocol | |
| Kākoʻo iā RSTP Rapid Spanning Tree Protocol | ||
| Kākoʻo ʻo MSTP Rapid Spanning Tree Protocol | ||
| Multicast | Kākoʻo i ka hoʻohui static, holoi | |
| IGMP-snooping | ||
| Kākoʻo iā MLD-Snooping | ||
| Kākoʻo v1/2/3 dynamic multicast monitor | ||
| DDM | Kākoʻo iā SFP/SFP+DDM | |
| Hana Hoʻonui | ||
| ACL | Ma muli o ke kumu MAC, kahi MAC, ʻano protocol, IP kumu, kahi e hele ai | |
| IP, L4 awa | ||
| QoS | Ma muli o ka 802.1p (COS). | |
| Ma muli o ka hoʻohālikelike DSCP | ||
| Hoʻokaʻawale ʻia ma muli o IP kumu, IP wahi e hele ai, a me ka helu awa | ||
| Kākoʻo SP, WRR hoʻolālā hoʻolālā | ||
| Kākoʻo kahe kahe palena palena CAR | ||
| LLDP | Kākoʻo i ka protocol ʻike loulou LLDP | |
| Nā hoʻonohonoho mea hoʻohana | Hoʻohui / holoi i nā mea hoʻohana | |
| Log | Hoʻokomo mea hoʻohana, hana, kūlana, hanana | |
| Kūʻē hoʻouka | pale DOS | |
| Kākoʻo i ka pale CPU a hoʻopaʻa i ka helu o ka hoʻouna ʻana i nā ʻeke CPU | ||
| Hoʻopaʻa ʻia ʻo ARP (IP, MAC, PORT ka hoʻopaʻa ʻana) | ||
| Palapala hōʻoia | Kākoʻo 802.1x awa hōʻoia | |
| Kākoʻo i ka palapala AAA | ||
| ʻIke pūnaewele | Kākoʻo ping, telnet, trace | |
| Hooponopono Pūnaewele | Hoʻihoʻi hou ʻana i ka hāmeʻa, hoʻonohonoho mālama / hoʻihoʻi, hoʻoponopono hoʻomaikaʻi, hoʻonohonoho manawa, etc. | |
| Hana hooponopono | ||
| CLI | Kākoʻo i ka hoʻokele laina kauoha port serial | |
| SSH | Kākoʻo SSHv1/2 hoʻokele mamao | |
| TELNET | Kākoʻo i ka hoʻokele mamao telnet | |
| WEB | Kākoʻo i nā hoʻonohonoho Layer 2, Layer 2 a me Layer 3 monitor | |
| SNMP | SNMP V1/V2/V3 | |
| Kākoʻo pahele: ColdStart, WarmStart, LinkDown, LinkUp | ||
| RMON | Kākoʻo iā RMON v1 | |
| PoE | Kākoʻo i ka lako mana PoE | |
| Nā hana ʻē aʻe | Kākoʻo iā DHCP Snooping, Option82, DHCP Server | |
| Kākoʻo i ka ʻike ARP ikaika | ||
| Kākoʻo i ka palapala hōʻoia TACACS + | ||
| Kākoʻo i ka hōʻoia DNS | ||
| Kākoʻo i nā hoʻonohonoho palekana awa | ||
| Kākoʻo i ka protocol MVR | ||
| Kākoʻo i ka hana VCT ʻike kelepona | ||
| Kākoʻo i ka protocol UDLD | ||