TH-G520-4SFP Hoʻololi Ethernet ʻOihana
ʻO TH-G520-4SFP he hanauna hou ʻo Industrial Managed Ethernet switch me 16-Port 10/100/1000Bas-TX a me 4-Port 100/1000 Base-FX Fast SFP e hāʻawi ana i ka hoʻoili ʻikepili kiʻekiʻe a me ka hoʻokele pūnaewele maikaʻi.
Loaʻa iā ia nā awa 16 Gigabit Ethernet me nā helu hoʻoili data a hiki i 1000Mbps, a me 4 SFP slots e kākoʻo ana i nā modula 100Mbps a me 1000Mbps SFP.
Kākoʻo ka TH-G520-4SFP i nā protocol he nui, me SNMP, CLI, Telnet, a me ka hoʻokele pūnaewele. Hāʻawi kēia i nā luna hoʻokele pūnaewele e nānā maʻalahi a hoʻokele i ka hele ʻana o ka pūnaewele, e hana mua
He hui ʻoihana mākou, he nui nā makahiki o kā mākou mau lālā i ka ʻoihana kālepa honua. He hui ʻōpio mākou, piha i ka hoʻoikaika a me ka hana hou. He hui hoʻolaʻa mākou. Hoʻohana mākou i nā huahana kūpono e hōʻoluʻolu i nā mea kūʻai aku a lanakila i kā lākou hilinaʻi. He hui mākou me nā moeʻuhane. ʻO kā mākou moemoeā maʻamau ka hāʻawi ʻana i nā mea kūʻai aku i nā huahana hilinaʻi a hoʻomaikaʻi pū. E hilinaʻi iā mākou, lanakila-lanakila.
● 16Nā awa x10/100/1000Base-TX RJ45, 4×100/1000Base-FX Nā awa SFP wikiwiki
● Kākoʻo 4Mbit packet buffer.
● Kākoʻo 10K bytes jumbo frame
● Kākoʻo iā IEEE802.3az ʻenehana Ethernet ʻoi aku ka ikaika
● Kākoʻo IEEE 802.3D/W/S maʻamau STP/RSTP/MSTP protocol
● -40 ~ 75 ° C wela hana no ka paʻakikī
● Kākoʻo iā ITU G.8032 maʻamau ERPS Redundant Ring protocol
● hoʻolālā pale polarity hoʻokomo mana
● pahu Aluminum, ʻaʻohe hoʻolālā peʻahi
● Ke ala hoʻokomo: DIN Rail / Wall kau ʻana
Inoa Hoʻohālike | wehewehe |
TH-G520-4SFP | Hoʻololi i ka ʻoihana me nā awa 16×10/100/1000Base-TX RJ45 a me nā awa 4×100/1000Base-FX SFP, lua uila komo mana 9~56VDC |
TH-G520-16E4SFP | Hoʻololi i ka ʻoihana me nā awa 16×10/100/1000Base-TX POE RJ45 a me nā awa 4×100/1000Base-FX SFP, lua mana hoʻokomo |
TH-G520-4SFP-H | Hoʻololi i ka ʻoihana me nā awa 16×10/100/1000Base-TX RJ45 a me nā awa 4x100/1000Base-FX SFP, hoʻokahi mana hoʻokomo uila 85-265VAC |
ʻIkepili Ethernet | ||
Awa | 16×10/100/1000BASE-TX RJ45, 4×100/1000BASE-X SFP | |
ʻO ka pahu hoʻokomo mana | ʻEono-pine pahu me 5.08mm pitch | |
Nā kūlana | IEEE 802.3 no 10BaseT IEEE 802.3u no 100BaseT(X) a me 100BaseFX IEEE 802.3ab no 1000BaseT(X) IEEE 802.3z no 1000BaseSX/LX/LHX/ZX IEEE 802.3x no ka mana kahe IEEE 802.1D-2004 no ka Spanning Tree Protocol IEEE 802.1w no Rapid Spanning Tree Protocol IEEE 802.1p no ka Papa Hana IEEE 802.1Q no ka hōʻailona VLAN | |
Ka nui o ka Packet Buffer | 4M | |
PacketLength kiʻekiʻe | 10K | |
Papa helu helu MAC | 8K | |
ʻAno hoʻouna | E kūʻai a i mua (ke ʻano piha/half duplex) | |
Waiwai Panai | Ka manawa lohi <7μs | |
Backplane bandwidth | 48Gbps | |
POE(koho) | ||
Nā kūlana POE | IEEE 802.3af/IEEE 802.3at POE | |
Hoʻohana POE | max 30W no ke awa | |
Ka mana | ||
Hookomo mana | Hoʻokomo mana pālua 9-56VDC no ka POE ʻole a me 48 ~ 56VDC no POE | |
Hoʻohana mana | Haawe piha<15W(non-POE); Haawe piha<495W(POE) | |
Nā ʻano kino | ||
Hale hale | pahu alumini | |
Anana | 160mm x 132mm x 70mm (L x W x H) | |
Kaumaha | 600g | |
ʻAno hoʻokomo | ʻO DIN Rail a me Wall Mounting | |
Kaiapuni Hana | ||
Ka Mahana Hana | -40 ℃~75 ℃ (-40 a 167 ℉) | |
ʻO ka haʻahaʻa hana | 5% ~ 90% (ʻaʻole condensing) | |
Ka Mahana Waihona | -40 ℃~85 ℃ (-40 a 185 ℉) | |
Palapala hōʻoia | ||
MTBF | 500000 hola | |
Manawa Kuleana Kuleana | 5 makahiki | |
Palapala hōʻoia
| FCC Māhele15 Papa A CE-EMC/LVD ROSH IEC 60068-2-27(Haʻalulu) IEC 60068-2-6(Haʻalulu) IEC 60068-2-32(Hāʻule manuahi) | IEC 61000-4-2(ESD):Papa 4 IEC 61000-4-3(Ua hoike mai o RS):Papa 4 IEC 61000-4-2(EFT):Papa 4 IEC 61000-4-2(Piʻi ʻana):Papa 4 IEC 61000-4-2(CS):Papa 3 IEC 61000-4-2(PFMP):Papa 5 |
Hana lako polokalamu | Pūnaehana Hoʻonui:kākoʻo iā STP/RSTP,ERPS Redundant Ring,manawa hoʻihoʻi <20ms | |
Multicast:IGMP Snooping V1/V2/V3 | ||
VLAN:IEEE 802.1Q 4K VLAN,GVRP, GMRP, QINQ | ||
Hui Hui:Dynamic IEEE 802.3ad LACP LINK Aggregation, Static Link Aggregation | ||
QOS: Kākoʻo Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA | ||
Mana Hoʻokele: CLI, hoʻokele pūnaewele, SNMP v1/v2C/V3, Telnet/SSH kikowaena no ka hoʻokele | ||
ʻO ka mālama ʻana i ka maʻi maʻi: hoʻohālikelike awa, Ping Command | ||
Ka hoʻomalu ʻana i ka hoʻāla ʻana: Relay warning, RMON, SNMP Trap | ||
Palekana: DHCP Server/Client,Koho 82,kākoʻo iā 802.1X,ACL, kākoʻo iā DDOS, | ||
Hoʻohou polokalamu ma o HTTP, ʻoi aku ka firmware e pale aku i ka hemahema |