TH-G512-4SFP Hoʻololi Ethernet ʻOihana
ʻO TH-G512-4SFP he hanauna hou ʻo Industrial Managed Ethernet Switch me 8-Port 10/100/1000Bas-TX a me 4-Port 100/1000 Base-FX Fast SFP e hāʻawi ana i kahi hoʻokele hoʻokele pūnaewele hoʻohana e hoʻomaʻamaʻa i ka hoʻonohonoho. a me nā hana nānā.
Hoʻolālā ʻia e hoʻohana ʻia i loko o nā ʻoihana ʻoihana koʻikoʻi, me kahi hale metala koʻikoʻi e hāʻawi i ka pale maikaʻi loa i nā mea kūlohelohe e like me ka lepo, ka haʻahaʻa, a me nā mahana wela. Loaʻa iā ia kahi ākea ākea ākea o -40 ° C a hiki i 75 ° C, kūpono ia no ka hoʻohana ʻana i nā ʻano ʻoihana like ʻole.
● Hoʻolauna i kā mākou huahana hou loa, 8×10/100/1000Base-TX RJ45 awa a me 4×100/1000Base-FX wikiwiki SFP awa. Hoʻolako ʻia me nā awa 8 RJ45 a me nā awa SFP 4, hāʻawi ka hoʻololi i kahi hoʻonā ʻenehana loea a hilinaʻi. Me 4Mbit packet buffer e hōʻoia i ka hoʻouna ʻana i ka ʻikepili maʻalahi a maikaʻi. Eia kekahi, kākoʻo ʻo ia i nā pahu jumbo 10K byte no ka hoʻoili ʻole ʻana i nā ʻāpana ʻikepili nui.
● Hoʻohana ka hoʻololi i ka ʻenehana Ethernet hoʻopakele ikehu IEEE802.3az e hoʻonui i ka hoʻohana mana a hoʻemi i nā kumukūʻai hana. Kākoʻo ʻo ia i ka IEEE 802.3D/W/S maʻamau STP/RSTP/MSTP protocol e hōʻoia i kahi pilina pūnaewele palekana a paʻa. Eia kekahi, loaʻa iā ia kahi pae wela hana o -40 ~ 75 ° C a me kahi hoʻolālā paʻakikī e kū i nā ʻano ʻino.
● I mea e hoʻonui ai i ka hilinaʻi pūnaewele, kākoʻo kā mākou mau hoʻololi i ka ITU G.8032 standard ERPS redundant ring protocol, hiki ke hoʻomaopopo i ka hoʻihoʻi ʻana o ka pūnaewele maʻemaʻe a me ka wikiwiki i ka wā o ka hāʻule. ʻO ka hoʻolālā pale polarity hoʻokomo mana e hōʻoia i ka palekana a pale i nā kaapuni pōkole uila.
● Hōʻike ka hoʻololi i kahi paʻa alumini a me kahi hoʻolālā fanless e hoʻonui i ka wela a hoʻoikaika i ka hana mālie. Hiki ke hoʻokomo maʻalahi me ka hoʻohana ʻana i ke ala i hāʻawi ʻia D, ka mea maʻalahi i ka hoʻonohonoho a me ka hoʻonohonoho ʻana.
● Ma ke ʻano holoʻokoʻa, ʻo kā mākou 8 10/100/1000Base-TX RJ45 awa a me 4 100/1000Base-FX wikiwiki SFP hoʻololi hoʻololi e hāʻawi i kahi hui ikaika o ka hoʻohui kiʻekiʻe, ka ikaika o ka ikehu, a me ka paʻa. ʻO ia ka hopena maikaʻi loa no nā ʻoihana e koi ana i kahi hoʻonā pūnaewele hilinaʻi i nā wahi paʻakikī.
Inoa Hoʻohālike | wehewehe |
TH-G512-4SFP | Hoʻololi i ka ʻoihana me nā awa 8 × 10/100/1000Base-TX RJ45 a me nā awa 4 × 100/1000Base-FX SFP, lua mana hoʻokomo uila9~56VDC |
TH-G512-8E4SFP | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX POE RJ45 a me nā awa 4×100/1000Base-FX SFP, lua uila komo mana 48~56VDC |
TH-G512-4SFP-H | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45 a me nā awa 4×100/1000Base-FX SFP 100~240VAC |
ʻIkepili Ethernet | ||
Awa | 8×10/100/1000BASE-TX RJ45, 4x1000BASE-X SFP | |
ʻO ka pahu hoʻokomo mana | ʻEono-pine pahu me 5.08mm pitch | |
Nā kūlana | IEEE 802.3 no 10BaseT IEEE 802.3u no 100BaseT(X) a me 100BaseFX IEEE 802.3ab no 1000BaseT(X) IEEE 802.3z no 1000BaseSX/LX/LHX/ZX IEEE 802.3x no ka mana kahe IEEE 802.1D-2004 no ka Spanning Tree Protocol IEEE 802.1w no Rapid Spanning Tree Protocol IEEE 802.1p no ka Papa Hana IEEE 802.1Q no ka hōʻailona VLAN | |
Ka nui o ka Packet Buffer | 4M | |
Ka lōʻihi o ka pūʻolo | 10K | |
Papa helu helu MAC | 8K | |
ʻAno hoʻouna | E kūʻai a i mua (ke ʻano piha/half duplex) | |
Waiwai Panai | Ka manawa lohi <7μs | |
Backplane bandwidth | 24Gbps | |
POE(koho) | ||
Nā kūlana POE | IEEE 802.3af/IEEE 802.3at POE | |
Hoʻohana POE | max 30W no ke awa | |
Ka mana | ||
Hookomo mana | Hoʻokomo mana pālua 9-56VDC no ka POE ʻole a me 48 ~ 56VDC no POE | |
Hoʻohana mana | Haawe piha<15W(non-POE); Haawe piha<255W(POE) | |
Nā ʻano kino | ||
Hale hale | pahu alumini | |
Anana | 138mm x 108mm x 49mm (L x W x H) | |
Kaumaha | 680g | |
ʻAno hoʻokomo | ʻO DIN Rail a me Wall Mounting | |
Kaiapuni Hana | ||
Ka Mahana Hana | -40 ℃~75 ℃ (-40 a 167 ℉) | |
ʻO ka haʻahaʻa hana | 5% ~ 90% (ʻaʻole condensing) | |
Ka Mahana Waihona | -40 ℃~85 ℃ (-40 a 185 ℉) | |
Palapala hōʻoia | ||
MTBF | 500000 hola | |
Manawa Kuleana Kuleana | 5 makahiki | |
Palapala hōʻoia
| FCC Māhele15 Papa A CE-EMC/LVD ROSH IEC 60068-2-27(Haʻalulu) IEC 60068-2-6(Haʻalulu) IEC 60068-2-32(Hāʻule manuahi) | IEC 61000-4-2(ESD):Papa 4 IEC 61000-4-3(Ua hoike mai o RS):Papa 4 IEC 61000-4-2(EFT):Papa 4 IEC 61000-4-2(Piʻi ʻana):Papa 4 IEC 61000-4-2(CS):Papa 3 IEC 61000-4-2(PFMP):Papa 5 |
Hana lako polokalamu | Pūnaehana Hoʻonui:kākoʻo iā STP/RSTP,ERPS Redundant Ring,manawa hoʻihoʻi <20ms | |
Multicast:IGMP Snooping V1/V2/V3 | ||
VLAN:IEEE 802.1Q 4K VLAN,GVRP, GMRP, QINQ | ||
Hui Hui:Dynamic IEEE 802.3ad LACP LINK Aggregation, Static Link Aggregation | ||
QOS: Kākoʻo Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA | ||
Mana Hoʻokele: CLI, hoʻokele pūnaewele, SNMP v1/v2C/V3, Telnet/SSH kikowaena no ka hoʻokele | ||
ʻO ka mālama ʻana i ka maʻi maʻi: hoʻohālikelike awa, Ping Command | ||
Ka hoʻomalu ʻana i ka hoʻāla ʻana: Relay warning, RMON, SNMP Trap | ||
Palekana: DHCP Server/Client,Koho 82,kākoʻo iā 802.1X,ACL, kākoʻo iā DDOS, | ||
Hoʻohou polokalamu ma o HTTP, ʻoi aku ka firmware e pale aku i ka hemahema |