TH-G510-8E2SFP Hoʻololi Ethernet ʻOihana
ʻO TH-G510-8E2SFP kahi kiʻekiʻe o ka Industrial Managed PoE Switch e kākoʻo ana i ka pilina Ethernet a me ka fiber optic.
Loaʻa iā ia nā awa 8 10/100/1000BASE-TX PoE RJ45 a me 2 100/1000BASE-X SFP awa, hiki ke hoʻohana ʻia no ka lawe ʻana i ka ʻikepili lōʻihi.
Hiki ke hoʻohana ʻia ka hoʻololi me ka hoʻohana ʻana i nā mana hoʻokomo ʻelua a kākoʻo iā IEEE 802.3af/at PoE standards, me ka hoʻohana nui ʻana o 30W no kēlā me kēia awa.
Loaʻa iā ia kahi pahu alumini paʻa a hiki ke hoʻokomo ʻia me ka hoʻohana ʻana i ka DIN rail a me ka hoʻopili ʻana i ka paia.
Kākoʻo pū ʻo ia i nā hana polokalamu like ʻole, me ka hōʻailona VLAN, QoS, a me ka hoʻokele ma o kahi kikowaena pūnaewele.
● 8×10/100/1000Base-TX PoE RJ45 awa, 2×100/1000Base-FX mau awa SFP wikiwiki
● Kākoʻo ʻo DIP Switch i ka RSTP/VLAN/SPEED.
● Kākoʻo i ka 9K bytes jumbo frame, kūpono me nā protocol extension like ʻole
● Kākoʻo iā IEEE802.3az ʻenehana Ethernet ʻoi aku ka ikaika
● Uila 4KV pale hoʻonui, maʻalahi e hoʻohana i kahi kaiapuni waho
●Hoʻolālā pale polarity komo mana
Inoa Hoʻohālike | wehewehe |
TH-G510-2SFP | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45 a me nā awa 2×100/1000Base-FX SFP 9~56VDC |
TH-G510-8E2SFP | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX POE RJ45 a me nā awa 2×100/1000Base-FX SFP 48~56VDC |
TH-G510-2SFP-H | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45 a me nā awa 2×100/1000Base-FX SFP 100~240VAC |
ʻIkepili Ethernet | |
Awa | 8×10/100/1000BASE-TX POE RJ45, 2x1000BASE-X SFP |
ʻO ka pahu hoʻokomo mana | ʻEono-pine pahu me 5.08mm pitch |
Nā kūlana | IEEE 802.3 no 10BaseTIEEE 802.3u no 100BaseT(X) a me 100BaseFX IEEE 802.3ab no 1000BaseT(X) IEEE 802.3z no 1000BaseSX/LX/LHX/ZX IEEE 802.3x no ka mana kahe IEEE 802.1D2004 no ka Spanning Tree Protocol IEEE 802.1w no Rapid Spanning Tree Protocol IEEE 802.1p no ka Papa Hana IEEE 802.1Q no ka hōʻailona VLAN |
Ka nui o ka Packet Buffer | 4M |
Ka lōʻihi o ka pūʻolo | 10K |
Papa helu helu MAC | 8K |
ʻAno hoʻouna | E kūʻai a i mua (ke ʻano piha/half duplex) |
Waiwai Panai | Ka manawa lohi <7μs |
Backplane bandwidth | 24Gbps |
POE(koho) | |
Nā kūlana POE | IEEE 802.3af/IEEE 802.3at POE |
Hoʻohana POE | max 30W no ke awa |
Ka mana | |
Hookomo mana | Hoʻokomo mana pālua 9-56VDC no ka POE ʻole a me 48 ~ 56VDC no POE |
Hoʻohana mana | Haawe piha<15W (POE ole); Haʻawe piha<255W (POE) |
Nā ʻano kino | |
Hale hale | pahu alumini |
Anana | 138mm x 108mm x 49mm (L x W x H) |
Kaumaha | 680g |
ʻAno hoʻokomo | ʻO DIN Rail a me Wall Mounting |
Kaiapuni Hana | |
Ka Mahana Hana | -40 ℃~75 ℃ (-40 a 167 ℉) |
ʻO ka haʻahaʻa hana | 5% ~ 90% (ʻaʻole condensing) |
Ka Mahana Waihona | -40 ℃~85 ℃ (-40 a 185 ℉) |
Palapala hōʻoia | |
MTBF | 500000 hola |
Manawa Kuleana Kuleana | 5 makahiki |
Palapala hōʻoia | FCC Part15 Papa A IEC 61000-4-2(ESD): Papa 4 CE-EMC/LVD IEC 61000-4-3(RS): Papa 4 ROSH IEC 61000-4-2(EFT): Papa 4 IEC 60068-2-27 (Hūhā) IEC 61000-4-2(Piʻi ʻana): Papa 4 IEC 60068-2-6 (Kuhi) IEC 61000-4-2(CS): Papa 3 IEC 60068-2-32 (Holo kūʻokoʻa) IEC 61000-4-2(PFMP): Papa 5 |
Hana lako polokalamu | Pūnaehana Redundant: kākoʻo iā STP/RSTP, ERPS Redundant Ring, manawa hoʻihoʻi <20ms |
Multicast: IGMP Snooping V1/V2/V3 | |
VLAN:IEEE 802.1Q 4K VLAN,GVRP ,GMRP,QINQ | |
Hui Pūʻulu: Dynamic IEEE 802.3ad LACP LINK Huihui, Static Link Aggregation | |
QOS: Kākoʻo Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA | |
Mana Hoʻokele: CLI, hoʻokele pūnaewele, SNMP v1/v2C/V3, Telnet/SSH kikowaena no ka hoʻokele | |
ʻO ka mālama ʻana i ka maʻi maʻi: hoʻohālikelike awa, Ping Command | |
ʻO ka hoʻomalu ʻana i ka hoʻāla: ʻōlelo aʻo Relay, RMON, SNMP Trap | |
Palekana: DHCP Server/Client,koho 82, kākoʻo 802.1X,ACL, kākoʻo iā DDOS, | |
Hoʻohou polokalamu ma o HTTP, ʻoi aku ka firmware e pale aku i ka hemahema |