TH-G510-2S2SFP Hoʻololi Ethernet ʻOihana
ʻO TH-G510-2S2SFP he hanauna hou ʻo Industrial Managed Ethernet Switch me 8-Port 10/100/1000Bas-TX, 2-Port 100/1000 Base-FX Fast SFP awa a me 2 RS485/232/433Series awa e hāʻawi maʻalahi serial- i-Ethernet hoʻohui a me ka pilina i kahi pūnaewele TCP/IP, hiki ke hoʻokele maikaʻi ʻia ka ʻōnaehana pūnaewele mamao ma o kāna pūnaewele hoʻokele pūnaewele, telnet, a me VCOM.
Kākoʻo ia i nā noi a me nā ʻano hana serial no ka alarm a i ʻole ka pilina IP address e mālama ai i ka manawa o ka luna hoʻomalu i ka ʻike ʻana a me ka ʻimi ʻana i nā pilikia pūnaewele me ka nānā ʻole ʻana i nā cabling a me nā mea hana. Loaʻa nā koho pili lehulehu no kahi ʻoihana pūnaewele nui pū kekahi.
● 8×10/100/1000Base-TX RJ45 awa, 2x100/1000Base-FX Fast SFP awa a me 2x RS485/232/433 awa
● Kākoʻo 4Mbit packet buffer
● Kākoʻo 10K bytes jumbo frame
● Kākoʻo iā IEEE802.3az ʻenehana Ethernet ʻoi aku ka ikaika
● Kākoʻo IEEE 802.3D/W/S maʻamau STP/RSTP/MSTP protocol
● 40 ~ 75 ° C wela hana no ka 'oʻoleʻa kaiapuni
● Kākoʻo iā ITU G.8032 maʻamau ERPS Redundant Ring protocol
● hoʻolālā pale polarity hoʻokomo mana
● pahu Aluminum, ʻaʻohe hoʻolālā peʻahi
● Ke ala hoʻokomo: DIN Rail / Wall kau ʻana
Inoa Hoʻohālike | wehewehe |
TH-G510-2S2SFP | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa pālua komo ʻelua 9~56VDC |
TH-G510-8E2S42FP | Hoʻololi hoʻokele ʻoihana me nā awa 8×10/100/1000Base-TX POE RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa pālua komo ʻelua 48~56VDC |
TH-G510-2S2SFP-H | Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa hoʻokomo hoʻokahi 100~240VAC |
ʻIkepili Ethernet | ||
Awa | 8×10/100/1000BASE-TX RJ45, 2x1000BASE-X SFP, 2x RS485/232/433 awa | |
ʻO ka pahu hoʻokomo mana | ʻEono-pine pahu me 5.08mm pitch | |
Nā kūlana | IEEE 802.3 no 10BaseT IEEE 802.3u no 100BaseT(X) a me 100BaseFX IEEE 802.3ab no 1000BaseT(X) IEEE 802.3z no 1000BaseSX/LX/LHX/ZX IEEE 802.3x no ka mana kahe IEEE 802.1D-2004 no ka Spanning Tree Protocol IEEE 802.1w no Rapid Spanning Tree Protocol IEEE 802.1p no ka Papa Hana IEEE 802.1Q no ka hōʻailona VLAN | |
Ka nui o ka Packet Buffer | 4M | |
Ka lōʻihi o ka pūʻolo | 10K | |
Papa helu helu MAC | 8K | |
ʻAno hoʻouna | E kūʻai a i mua (ke ʻano piha/half duplex) | |
Waiwai Panai | Ka manawa lohi <7μs | |
Backplane bandwidth | 24Gbps | |
POE(koho) | ||
Nā kūlana POE | IEEE 802.3af/IEEE 802.3at POE | |
Hoʻohana POE | max 30W no ke awa | |
Ka mana | ||
Hookomo mana | Hoʻokomo mana pālua 9-56VDC no ka POE ʻole a me 48 ~ 56VDC no POE | |
Hoʻohana mana | Haawe piha<15W(non-POE); Haawe piha<255W(POE) | |
Nā ʻano kino | ||
Hale hale | pahu alumini | |
Anana | 138mm x 108mm x 49mm (L x W x H) | |
Kaumaha | 680g | |
ʻAno hoʻokomo | ʻO DIN Rail a me Wall Mounting | |
Kaiapuni Hana | ||
Ka Mahana Hana | -40 ℃~75 ℃ (-40 a 167 ℉) | |
ʻO ka haʻahaʻa hana | 5% ~ 90% (ʻaʻole condensing) | |
Ka Mahana Waihona | -40 ℃~85 ℃ (-40 a 185 ℉) | |
Palapala hōʻoia | ||
MTBF | 500000 hola | |
Manawa Kuleana Kuleana | 5 makahiki | |
Hana awa Serial | 2x RS485/232/433 awa | |
ʻO ka wehewehe ʻana i ke awa serial | Nā hōʻailona RS-232: a: TXD, b: RXD, c: Na, d: Na, e:GND Nā hōʻailona RS-422: a: T+, b: T-, c: R+, d: R-, e:GND Nā hōʻailona RS-485: a: Na, b: Na, c: D+, d: D-, e:GND Ka nui o ka Baud: 2400-115200bps Puka huikau: 5-kūlana pahu pahu Hiki i ka ukana: Kākoʻo ka ʻaoʻao RS-485/422 i ka ʻāina koho balota 128 Mana kuhikuhi: RS-485 apono 'ikepili kahe kuhikuhi 'akomi mana 'enehana ʻO RS-232 pale interface: pale electrostatic 15KV ʻO RS-485/422 ka pale ʻana o ke kikowaena: kaʻawale kaʻawale 2KV, electrostatic pale 15KV
| |
Palapala hōʻoia | FCC Māhele15 Papa A CE-EMC/LVD ROSH IEC 60068-2-27(Haʻalulu) IEC 60068-2-6(Haʻalulu) IEC 60068-2-32(Hāʻule manuahi) | IEC 61000-4-2(ESD):Papa 4 IEC 61000-4-3(RS):Papa 4 IEC 61000-4-2(EFT):Papa 4 IEC 61000-4-2(Piʻi ʻana):Papa 4 IEC 61000-4-2(CS):Papa 3 IEC 61000-4-2(PFMP):Papa 5 |
Hana lako polokalamu | Pūnaehana Hoʻonui:kākoʻo iā STP/RSTP,ERPS Redundant Ring,manawa hoʻihoʻi <20ms | |
Multicast:IGMP Snooping V1/V2/V3 | ||
VLAN:IEEE 802.1Q 4K VLAN,GVRP, GMRP, QINQ | ||
Hui Hui:Dynamic IEEE 802.3ad LACP LINK Aggregation, Static Link Aggregation | ||
QOS: Kākoʻo Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA | ||
Mana Hoʻokele: CLI, hoʻokele pūnaewele, SNMP v1/v2C/V3, Telnet/SSH kikowaena no ka hoʻokele | ||
ʻO ka mālama ʻana i ka maʻi maʻi: hoʻohālikelike awa, Ping Command | ||
ʻO ka hoʻomalu ʻana i ka hoʻāla: ʻōlelo aʻo Relay, RMON, SNMP Trap | ||
Palekana: DHCP Server/Client,Koho 82,kākoʻo iā 802.1X,ACL, kākoʻo iā DDOS, | ||
Hoʻohou polokalamu ma o HTTP, ʻoi aku ka firmware e pale aku i ka hemahema |