TH-G510-2S2SFP Hoʻololi Ethernet ʻOihana

Helu Kumu:TH-G510-2S2SFP

Brand:Todahika

  • 8×10/100/1000Base-TX RJ45 awa, 2x100/1000Base-FX Fast SFP awa a me 2x RS485/232/433 awa
  • Kākoʻo i ka 10K bytes jumbo frame

Huahana Huahana

Nā hiʻohiʻona

ʻIke Kauoha

Nā kikoʻī

Anana

Huahana Huahana

Hōʻike huahana

ʻO TH-G510-2S2SFP he hanauna hou ʻo Industrial Managed Ethernet Switch me 8-Port 10/100/1000Bas-TX, 2-Port 100/1000 Base-FX Fast SFP awa a me 2 RS485/232/433Series awa e hāʻawi maʻalahi serial- i-Ethernet hoʻohui a me ka pilina i kahi pūnaewele TCP/IP, hiki ke hoʻokele maikaʻi ʻia ka ʻōnaehana pūnaewele mamao ma o kāna pūnaewele hoʻokele pūnaewele, telnet, a me VCOM.

Kākoʻo ia i nā noi a me nā ʻano hana serial no ka alarm a i ʻole ka pilina IP address e mālama ai i ka manawa o ka luna hoʻomalu i ka ʻike ʻana a me ka ʻimi ʻana i nā pilikia pūnaewele me ka nānā ʻole ʻana i nā cabling a me nā mea hana. Loaʻa nā koho pili lehulehu no kahi ʻoihana pūnaewele nui pū kekahi.

TH-8G0024M2P

  • Mua:
  • Aʻe:

  • ● 8×10/100/1000Base-TX RJ45 awa, 2x100/1000Base-FX Fast SFP awa a me 2x RS485/232/433 awa

    ● Kākoʻo 4Mbit packet buffer

    ● Kākoʻo 10K bytes jumbo frame

    ● Kākoʻo iā IEEE802.3az ʻenehana Ethernet ʻoi aku ka ikaika

    ● Kākoʻo IEEE 802.3D/W/S maʻamau STP/RSTP/MSTP protocol

    ● 40 ~ 75 ° C wela hana no ka 'oʻoleʻa kaiapuni

    ● Kākoʻo iā ITU G.8032 maʻamau ERPS Redundant Ring protocol

    ● hoʻolālā pale polarity hoʻokomo mana

    ● pahu Aluminum, ʻaʻohe hoʻolālā peʻahi

    ● Ke ala hoʻokomo: DIN Rail / Wall kau ʻana

    Inoa Hoʻohālike wehewehe
    TH-G510-2S2SFP Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa pālua komo ʻelua 956VDC
    TH-G510-8E2S42FP Hoʻololi hoʻokele ʻoihana me nā awa 8×10/100/1000Base-TX POE RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa pālua komo ʻelua 4856VDC
    TH-G510-2S2SFP-H Hoʻololi i ka ʻoihana me nā awa 8×10/100/1000Base-TX RJ45, 2 × 100/1000Base-FX SFP awa a me 2x RS485/232/433 mau awa hoʻokomo hoʻokahi 100240VAC
    ʻIkepili Ethernet
    Awa 8×10/100/1000BASE-TX RJ45, 2x1000BASE-X SFP, 2x RS485/232/433 awa
    ʻO ka pahu hoʻokomo mana ʻEono-pine pahu me 5.08mm pitch
    Nā kūlana IEEE 802.3 no 10BaseT

    IEEE 802.3u no 100BaseT(X) a me 100BaseFX

    IEEE 802.3ab no 1000BaseT(X)

    IEEE 802.3z no 1000BaseSX/LX/LHX/ZX

    IEEE 802.3x no ka mana kahe

    IEEE 802.1D-2004 no ka Spanning Tree Protocol

    IEEE 802.1w no Rapid Spanning Tree Protocol

    IEEE 802.1p no ka Papa Hana

    IEEE 802.1Q no ka hōʻailona VLAN

    Ka nui o ka Packet Buffer 4M
    Ka lōʻihi o ka pūʻolo 10K
    Papa helu helu MAC 8K
    ʻAno hoʻouna E kūʻai a i mua (ke ʻano piha/half duplex)
    Waiwai Panai Ka manawa lohi <7μs
    Backplane bandwidth 24Gbps
    POEkoho
    Nā kūlana POE IEEE 802.3af/IEEE 802.3at POE
    Hoʻohana POE max 30W no ke awa
    Ka mana
    Hookomo mana Hoʻokomo mana pālua 9-56VDC no ka POE ʻole a me 48 ~ 56VDC no POE
    Hoʻohana mana Haawe piha<15Wnon-POE); Haawe piha<255WPOE)
    Nā ʻano kino
    Hale hale pahu alumini
    Anana 138mm x 108mm x 49mm (L x W x H)
    Kaumaha 680g
    ʻAno hoʻokomo ʻO DIN Rail a me Wall Mounting
    Kaiapuni Hana
    Ka Mahana Hana -40 ℃~75 ℃ (-40 a 167 ℉)
    ʻO ka haʻahaʻa hana 5% ~ 90% (ʻaʻole condensing)
    Ka Mahana Waihona -40 ℃~85 ℃ (-40 a 185 ℉)
    Palapala hōʻoia
    MTBF 500000 hola
    Manawa Kuleana Kuleana 5 makahiki
    Hana awa Serial 2x RS485/232/433 awa
    ʻO ka wehewehe ʻana i ke awa serial Nā hōʻailona RS-232: a: TXD, b: RXD, c: Na, d: Na, e:GND

    Nā hōʻailona RS-422: a: T+, b: T-, c: R+, d: R-, e:GND

    Nā hōʻailona RS-485: a: Na, b: Na, c: D+, d: D-, e:GND

    Ka nui o ka Baud: 2400-115200bps

    Puka huikau: 5-kūlana pahu pahu Hiki i ka ukana:

    Kākoʻo ka ʻaoʻao RS-485/422 i ka ʻāina koho balota 128

    Mana kuhikuhi: RS-485 apono 'ikepili kahe kuhikuhi 'akomi mana 'enehana

    ʻO RS-232 pale interface: pale electrostatic 15KV

    ʻO RS-485/422 ka pale ʻana o ke kikowaena: kaʻawale kaʻawale 2KV, electrostatic pale 15KV

     

    Palapala hōʻoia FCC Māhele15 Papa A

    CE-EMC/LVD

    ROSH

    IEC 60068-2-27Haʻalulu

    IEC 60068-2-6Haʻalulu

    IEC 60068-2-32Hāʻule manuahi

    IEC 61000-4-2ESD):Papa 4

    IEC 61000-4-3RS):Papa 4

    IEC 61000-4-2EFT):Papa 4

    IEC 61000-4-2Piʻi ʻana):Papa 4

    IEC 61000-4-2CS):Papa 3

    IEC 61000-4-2PFMP):Papa 5

    Hana lako polokalamu Pūnaehana Hoʻonuikākoʻo iā STP/RSTPERPS Redundant Ringmanawa hoʻihoʻi <20ms
    MulticastIGMP Snooping V1/V2/V3
    VLANIEEE 802.1Q 4K VLANGVRP, GMRP, QINQ
    Hui HuiDynamic IEEE 802.3ad LACP LINK Aggregation, Static Link Aggregation
    QOS: Kākoʻo Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA
    Mana Hoʻokele: CLI, hoʻokele pūnaewele, SNMP v1/v2C/V3, Telnet/SSH kikowaena no ka hoʻokele
    ʻO ka mālama ʻana i ka maʻi maʻi: hoʻohālikelike awa, Ping Command
    ʻO ka hoʻomalu ʻana i ka hoʻāla: ʻōlelo aʻo Relay, RMON, SNMP Trap
    Palekana: DHCP Server/ClientKoho 82kākoʻo iā 802.1XACL, kākoʻo iā DDOS
    Hoʻohou polokalamu ma o HTTP, ʻoi aku ka firmware e pale aku i ka hemahema

    9

    E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou